Lutron Derating Charts


About Ganging

Ganging is the mounting of two or more controls side-by-side in a series of connected wallboxes. Scored break-off fins along each side of the control’s mounting plate are designed to be removed to facilitate ganging in a single existing wallbox. Removal of the fins decreases the control’s ability to dissipate heat and thus reduces the current carrying capacity of the control.

If you are uncertain of your ability to correctly select or install Lutron or any other electrical products, you should consult with a qualified electrical contractor or technician before ordering or installing.

Ganging and Derating for Lutron Wallbox  Dimmers

Derating is the reduction of the maximum capacity (load) a dimmer can  reliably handle when the side sections (fins) are removed.

Vareo, Nova T*, Nova and Centurion dimmers may be ganged without removing the side sections - no derating required. Side sections can be removed to save space or have ganged units fit into existing wallboxes - derating required (side sections must be removed if using VWP Vareo wallplates for Vareo  wallplates for Vareo dimmers or tap switches).

Lumea2, Maestro, Diva, Skylark, Ariadni, Faedra, Glyder and Rotary dimmers must remove side sections to gang - derating required.

Athena dimmers have no removable side sections and derating is not required.

Click To Jump To The De-Rating Charts

Planning a Multigang Installation

STEP 1

Determine if the side sections are to be removed or to remain intact (applicable to Vareo, NovaT*, Nova, Centurion).

Consider: width of application, load, number of wallboxes  required, product type and side section breakoff options.

Control Widths (for determining width of a ganged installation)

Control Size

Width

.

Side Sections
Intact

One Side
Removed

Two Sides Removed

Small

2 3/4"

2 1/4"

1 3/4"

Large

4 1/2"

4 1/8"

3 5/8"

Note:

  • All Vareo models are considered "small" controls
  • For control sizes of Nova T* and Nova dimmers:
    • 600W and 1000W models are "small" controls
    • 1500W and 2000W models are "large" controls
  • For control sizes of Centurion and Athena dimmers:
    • 600W and 1000W models are "small" controls
    • 1500W and 2000W models are "large" controls
  • All Lumea2, Maestro, Diva, Ariadni, Faedra, Glyder and Rotary models are considered "small" controls

STEP 2

Use the capacity derating charts to determine maximum  permissible loads for each control in the installation if side sections will be removed.

STEP 3

Determine number of wallboxes required and plan control  placements in gang (see charts below):

Wallboxes Required - ALL SIDE SECTIONS INTACT

.

Number of Small Controls

Number of Large Controls

0

1

2

3

4

5

6

0

0

1

1+1*

4

4+1*

7

7+1*

1

1

3

5

6

8

9

11

2

4

6

7

9

10

12

13

3

6

8

10

11

13

14

16

4

9

11

12

14

15

17

18

Note:  When ganging an even number of small controls  with no side sections removed, use wallboxes with tapped ears as shown below. Do not use plastic rings or gangbox covers. Space an additional wallbox 3/4" apart  from the other wallbox(es). A 3/4" chase nipple is recommended as a spacer  between the wallboxes.

Example: Wallbox arrangement required for gang of 4 small controls, side sections intact:

Assembling The Controls:   When ganging any combination of small and large controls,  place a small control on one extreme end of the gang, and a large control at the  other end of the gang. Use center and offset mounting holes as  necessary.

Wallboxes Required - ALL INSIDE SECTIONS REMOVED

.

Number of Small Controls

Number of Large Controls

0

1

2

3

4

5

6

0

0

1

2

3

4

5

6

1

1

3

4

5

6

7

8

2

3

5

6

7

8

9

10

3

5

7

8

9

10

11

12

4

7

9

10

11

12

13

14

Removing Inner Side Sections

When removing side sections, remove only inner side  sections. Do not remove side sections on outer ends of the gang.

Assembling the Controls

When ganging any combination of small and large controls,  place a small control on one extreme end of the gang and a large control at the other end of the gang. Use center and offset mounting holes as  necessary.

STEP 4

Determine your multigang wallplate requirements

CAPACITY DERATING CHARTS

Vareo1,2 and Nova T*1,2 Products

.

CONTROL TYPE

No side sections removed (full capacity)

One side section removed

Middle unit has two side sections removed

DIMMERS

MAXIMUM CAPACITY

Incandescent

600W

500W

300W

1000W

900W

700W

1500W

1250W

1000W

1950W 5

--

--

MagneticLow Voltage

600VA

500VA

300VA

(450W)

(400W)

(250W)

1000VA

900VA

700VA

(800W)

(750W)

(500W)

1500VA

1250VA

1000VA

(1200W)

(1000W)

(800W)

Electronic Low Voltage

300W

300W

250W

600W

500W

400W

Fluorescent

Hi-Lume/ Eco-10 (ECO Series)

.

.

.

Vareo

20 Ballasts/ 8 A

20 Ballasts / 6A

20 Ballasts / 4.5A

Nova T*

6A

No derating required

No derating required

8A

No derating required

No derating required

16A

No derating required

No derating required

Eco-10 (TVE Series) 0-10 VDC

60 ballasts / 16A

No derating required

No derating required

Tu-Wire 3

5A

4A

3.3A

Fan Speed Controls

Quiet Controls4

1.5A

1.5A

1.5A

FullyVariable Controls

6A

4.2A

2.5A

12A

10A

8.3A

Electronic Tapswitches6

1000W/VA

800W/VA

650W/VA

Footnotes:

1 Controls must have  side sections removed to gang if using "VWP Series" wallplates
2 Recommended minimum 40 watt load
3 Minimum capacity: 2 ballasts/2.5 A
4 For use with only one ceiling paddle fan; prevents motor hum
5 For NT-2000 only.  Do not break fins/side  sections
6 VETS-R auxiliary electronics do not require derating

Nova and Centurion Products

.

CONTROL TYPE

No side sections removed (full capacity)

One side section removed

Middle unit has two side sections removed

DIMMERS

MAXIMUM CAPACITY

Incandescent

600W

600W

500W

.

1000W

900W

700W

.

1500W

1250W

1000W

.

2000W

1800W

1500W

Magnetic Low Voltage

600VA

600VA

500VA

.

(450W)

(450W)

(400W)

.

1000VA

900VA

700VA

.

(800W)

(750W)

(500W)

.

1500VA

1250VA

1000VA

.

(1200W)

(1000W)

(800W)

.

2000VA

1800VA

1500VA

.

(1600W)

(1500W)

(1200W)

Electronic Low Voltage

450W

400W

350W

Fluorescent

Nova controls may be used with either  Lutron Hi-lume electronic dimming ballasts or magnetic dimming ballasts. Controls used with electronic dimming ballasts do not require derating.

FAN-SPEED CONTROLS

.

Fully Variable Controls

6A

5.5A

5A

.

12A

11A

10A

Ariadni, Diva, Diva Satin Colors, Faedra1,

Glyder, Luméa2, Maestro1, RadioRA, Rotary,

Spacer1, and Spacer System1

.

CONTROL TYPE

No side sections removed (full capacity)

One side section removed

Middle unit has two side sections removed

DIMMERS

MAXIMUM CAPACITY

Incandescent2

600W

500W

400W

1000W

800W

650W

Dual Slide Dimmers

300W/300W

250W/250W

200W/200W

MagneticLow Voltage2

600VA

500VA

400VA

(450W)

(375W)

(300W)

1000VA

800VA

650VA

(800W)

(650W)

(500W)

Electronic Low Voltage

300W

250W

200W

600W

500W

400W

Fluorescent

Hi-Lume/ Eco-10 (ECO and TVE Series)

20 Ballasts / 6 A

No derating required

No derating required

8A

No derating required

No derating required

Tu-Wire

5A

4A

3.3A

FAN SPEED CONTROLS

Quiet Controls4

1.5A

No derating required

No derating required

FullyVariable Controls5

5A

4A

3A

10A

cannot gang

cannot gang

FAN/LIGHT CONTROLS

Quiet Controls4

Skylark

1.5A/360W

No derating required

No derating required

Skylark

1.5A/300W

No derating required

No derating required

Lumea2

1.5A/600W

No derating required

No derating required

Fully Variable5

Skylark

5A/360W

4A/360W

3A/360W

Skylark

2.5A/300W

2.1A/250W

1.7A/200W

Electronic Switches

RadioRA

8A

6.5A

5A

Spacer System

6A

5A

3.5A

Footnotes:

1 Accessory dimmers/accessory switches for Spacer System, Spacer, RadioRA, Faedra, and Maestro Smart Remotes do not require derating.
2 Minimum loads:  40W for Maestro, Faedra, and Spacer dimmers; 60W for Spacer System dimmers, 50W for RadioRA dimmers
3 Minimum capacity: 2 ballasts, 2.5A
4 For use with one ceiling paddle fan; prevents motor hum
5 Total fan plus light load may not exceed 2.5A

If you are uncertain of your ability to correctly select or install Lutron or any other electrical products, you should consult with a qualified electrical contractor or technician before ordering or installing.

Home Products Specials About Us Contact Us Newsletter Terms-Conditions

  Shipping Taxes Payment Return Authorization Privacy-Security

 

 

© 2006 Allen Electric Supply Co.   All rights reserved.  ElectricalDeals.Com and its logo are registered service marks of Allen Electric Supply Co.  Published by Allen Electric Supply Co. All brand or product names used throughout this website are trademarks of their respective holders.  Other websites wishing to link to this website are authorized only to link to our homepage with the provision that our site will not be framed within the other website.